Acoustic leak detection of LMFBR steam generator
Creators
- 1. Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.
Description
The development of a water leak detector with short response time for LMFBR steam generators is required to prevent the failure propagation caused by the sodium-water reaction and to maintain structural safety in steam generators. The development of an acoustic leak detector assuring short response time has attracted. The purpose of this paper is to confirm the basic detection feasibility of the active acoustic leak detector, and to investigate the leak detection method by erasing the background noise by spectrum analysis of the passive acoustic leak detector. From a comparison of the leak detection sensitivity of the active and the passive method, the active method is not influenced remarkably by the background noise, and it has possibility to detect microleakage with short response time. We anticipate a practical application of the active method in the future. (author)
Additional details
Publishing Information
- Journal Title
- Denryoku Chuo Kenkyusho Hokoku
- Journal Issue
- no.T92079
- Journal Page Range
- p. 1-56.
- CODEN
- DCKHDL
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 25022794
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ACOUSTIC MONITORING; FEASIBILITY STUDIES; LEAK DETECTORS; LMFBR TYPE REACTORS; PERFORMANCE TESTING; SODIUM; STEAM GENERATORS; WATER
- Descriptors DEC
- ALKALI METALS; BOILERS; BREEDER REACTORS; ELEMENTS; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; HYDROGEN COMPOUNDS; LIQUID METAL COOLED REACTORS; METALS; MONITORING; OXYGEN COMPOUNDS; REACTORS; TESTING; VAPOR GENERATORS