Published 1995 | Version v1
Miscellaneous Open

Point Lepreau NGS RTD cable assembly failure and replacement program

  • 1. New Brunswick Power, Fredericton, NB (Canada)

Description

The purpose of this report is to Provide a review of the RTD (Resistance Temperature Detector) cable assemblies problems experienced at Point Lepreau Generating Station, and to discuss both the interim repair performed during the '92 and '93 outages to gather with the design and testing and installation of a qualified alternative. (author)