Predictive value of PWI for blood supply and T1-spin echo MRI for consistency of pituitary adenoma
Creators
- 1. Shanghai Pituitary Tumor Center, Shanghai (China)
- 2. Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Shanghai (China)
- 3. Fudan University, Department of Radiology, Huashan Hospital, Shanghai Medical College, Shanghai (China)
- 4. Fudan University, Department of Neuropathology, Huashan Hospital, Shanghai Medical College, Shanghai (China)
Description
It is a common view that consistency and blood supply of pituitary adenoma (PA) can influence the surgical effect. The aim of this study was to determine whether MRI signal intensity (SI) was correlated to the consistency or blood supply of pituitary macroadenoma. Forty eight pituitary macroadenoma patients were underwent preoperative MRI, including precontrast and contrast-enhanced (CE) T1-spin echo (T1-SE) imaging, CE-sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) imaging, and perfusion-weighted imaging (PWI). The tumor consistency and blood supply were determined by neurosurgeons. The expression of collagen IV and MIB-1 was detected with immunohistology. The correlation of the relative SI (rSI) values (tumor to normal frontal white matter SI) and PWI data to the tumor consistency, blood supply, and the expression level of collagen IV and MIB-1 was statistically studied by Kruskal-Wallis rank test (K-W test). A significant correlation was observed between the tumor consistency and the rSI on precontrast T1-SE imaging (P = 0.004) but not on CE T1-SE and CE SPACE imaging. The expression of collagen IV was also significantly associated with rSI on T1-SE imaging (P = 0.010). The blood supply was correlated with the relative CBV (rCBV) (P = 0.030). In addition, the expression of MIB-1 was correlated with rSI of CE T1-SE imaging (P = 0.007). Our results suggest that T1-SE imaging may be a simple and useful method for predicting consistency of PA. CBV value can provide helpful information for assessing the blood supply of pituitary macroadenoma. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00234-015-1591-8Additional details
Identifiers
Publishing Information
- Journal Title
- Neuroradiology
- Journal Volume
- 58
- Journal Issue
- 1
- Journal Page Range
- p. 51-57
- ISSN
- 0028-3940
- CODEN
- NRDYAB
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 47040343
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ADENOMAS; BLOOD CIRCULATION; BLOOD FLOW; COLLAGEN; FORECASTING; HEMORRHAGE; IMAGE PROCESSING; NMR IMAGING; PITUITARY GLAND; RELAXATION TIME; SPIN ECHO; SURGERY; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; CARCINOMAS; DIAGNOSTIC TECHNIQUES; DISEASES; ENDOCRINE GLANDS; FUNCTIONS; GLANDS; MEDICINE; NEOPLASMS; ORGANIC COMPOUNDS; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; PROTEINS; SCLEROPROTEINS; SYMPTOMS