Measurement uncertainty in pulmonary vascular input impedance and characteristic impedance estimated from pulsed-wave Doppler ultrasound and pressure: clinical studies on 57 pediatric patients
- 1. Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80309 (United States)
- 2. Department of Pediatric Cardiology, The Children's Hospital, University of Colorado at Denver, Aurora, CO 80045 (United States)
Description
Pulmonary vascular input impedance better characterizes right ventricular (RV) afterload and disease outcomes in pulmonary hypertension compared to the standard clinical diagnostic, pulmonary vascular resistance (PVR). Early efforts to measure impedance were not routine, involving open-chest measurement. Recently, the use of pulsed-wave (PW) Doppler-measured velocity to non-invasively estimate instantaneous flow has made impedance measurement more practical. One critical concern remains with clinical use: the measurement uncertainty, especially since previous studies only incorporated random error. This study utilized data from a large pediatric patient population to comprehensively examine the systematic and random error contributions to the total impedance uncertainty and determined the least error prone methodology to compute impedance from among four different methods. We found that the systematic error contributes greatly to the total uncertainty and that one of the four methods had significantly smaller propagated uncertainty; however, even when this best method is used, the uncertainty can be large for input impedance at high harmonics and for the characteristic impedance modulus. Finally, we found that uncertainty in impedance between normotensive and hypertensive patient groups displays no significant difference. It is concluded that clinical impedance measurement would be most improved by advancements in instrumentation, and the best computation method is proposed for future clinical use of the input impedance
Availability note (English)
Available from http://dx.doi.org/10.1088/0967-3334/31/6/001Additional details
Identifiers
- DOI
- 10.1088/0967-3334/31/6/001;
- PII
- S0967-3334(10)30761-1;
Publishing Information
- Journal Title
- Physiological Measurement (Print)
- Journal Volume
- 31
- Journal Issue
- 6
- Journal Page Range
- p. 729-748
- ISSN
- 0967-3334
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47046440
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Descriptors DEI
- CALCULATION METHODS; CHEST; COMPARATIVE EVALUATIONS; DATA COVARIANCES; DOPPLER EFFECT; ERRORS; HARMONICS; HYPERTENSION; IMPEDANCE; PATIENTS; PEDIATRICS; PULSES; RANDOMNESS; ULTRASONOGRAPHY
- Descriptors DEC
- BODY; CARDIOVASCULAR DISEASES; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; MEDICINE; OSCILLATIONS; SYMPTOMS; VASCULAR DISEASES