Published August 2009 | Version v1
Journal article

Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint

  • 1. University Hospitals - Campus Grosshadern, Ludwig Maximilians University of Munich, Department of Clinical Radiology, Munich (Germany)
  • 2. University of California, Musculoskeletal and Quantitative Imaging Group, Department of Radiology, San Francisco, CA (United States)
  • 3. General Electrics Healthcare Technologies, San Francisco, CA (United States)
  • 4. University of California, Department of Orthopedic Surgery, San Francisco, CA (United States)

Description

The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. At 7.0 T, SNR was increased (p<0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p<0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p<0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p < 0.05) at 7.0 T due to limited performance of IM-w FSE. Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00256-009-0676-z

Additional details

Identifiers

Publishing Information

Journal Title
Skeletal Radiology
Journal Volume
38
Journal Issue
8
Journal Page Range
p. 771-783
ISSN
0364-2348
CODEN
SKRADI

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
40085122
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARTILAGE; COMPARATIVE EVALUATIONS; NMR IMAGING
Descriptors DEC
ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; EVALUATION