Published November 2007 | Version v1
Journal article

Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: a quantitative comparison study

  • 1. Kyoto University Graduate School of Medicine, Department of Diagnostic Imaging and Nuclear Medicine, Kyoto (Japan)
  • 2. Kyoto University Graduate School of Medicine, Human Brain Research Center, Kyoto (Japan)
  • 3. National Institute of Neuroscience, National Center of Neurology and Psychiatry, Department of Cortical Function Disorders, Kyoto (Japan)

Description

Discrepancies exist in the literature regarding contrast between gray and white matter on spin-echo (SE) T1-weighted MR imaging at 3 T. The present study quantitatively assessed differences in gray matter-white matter contrast on both single- and multi-slice SE T1-weighted imaging between 3 and 1.5 T. SE T1-weighted sequences with the same parameters at both 3 and 1.5 T were used. Contrast-to-noise ratio (CNR) between gray and white matter (CNRGM-WM) was evaluated for both frontal lobes. To assess the effects of interslice gap, multi-slice images were obtained with both 0 and 25% interslice gap. Single-slice CNRGM-WM was higher at 3 T (17.66 ± 2.68) than at 1.5 T (13.09 ± 2.35; P < 0.001). No significant difference in CNRGM-WM of multi-slice images with 0% gap was noted between 3 and 1.5 T (3T, 8.61 ± 2.55; 1.5T, 7.43 ± 1.20; P > 0.05). Multi-slice CNRGM-WM with 25% gap was higher at 3T (12.47 ± 3.31) than at 1.5 T (9.73 ± 1.37; P < 0.001). CNRGM-WM reduction rate of multi-slice images with 0% gap compared with single-slice images was higher at 3T (0.47 ± 0.13) than at 1.5 T (0.38 ± 0.09; P = 0.02). CNRGM-WM on single-slice SE T1-weighted imaging and CNRGM-WM on multi-slice images with 25% interslice gap were better at 3 T than at 1.5 T. The influence of multi-slice imaging on CNRGM-WM was significantly larger at 3T than at 1.5 T. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-007-0688-9

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
17
Journal Issue
11
Journal Page Range
p. 2921-2925
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
38115909
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BRAIN; NMR IMAGING; SPIN ECHO
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; NERVOUS SYSTEM; ORGANS