Published September 1999 | Version v1
Book

Limiting plutonium and minor actinides inventory: comparison between accelerator driven system (ADS) and critical reactor

  • 1. EDF, Research and Development Division, 1 avenue du General de Gaulle, 92141 Clamart (France)
  • 2. EDF, Engineering and Services Division, 22 et 30 avenue de Wagram, 75382 Paris (France)
  • 3. CEA, Nuclear Reactor Division, Centre d'Etudes de Cadarache, 13108, St Paul lez Durance (France)

Description

This paper deals with different possibilities to reduce the transuranium elements (TRU) inventories in a park of reactors involving critical or subcritical transmutation systems. AMSTER, a critical, graphite moderated molten salt concept which uses an enriched uranium fuel, appears as the most efficient in comparison with others systems

Additional details

Publishing Information

Publisher
American Nuclear Society - ANS
Imprint Place
Jackson Hole, Wyoming (United States)
Imprint Pagination
10 p.

Conference

Title
International Conference on Future Nuclear Systems - Nuclear Technology - Bridging the Millennia
Acronym
Global'99
Dates
29 Aug - 3 Sep 1999
Place
Las Vegas, NV (United States)

Optional Information

Notes
11 refs.; available from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (US)