The quality of a series of uranium calibration standards and a series of plutonium calibration standards for the segmented gamma scanning (SGS) was verified. It is important to analyze the proper quality of the special nuclear material in the standards and its homogeneity in the matrix was measured by gamma ray non-destructive assay (NDA). As a result, the measured values of each series standards are agreeable with declared within 1%. And the measured results of the material uniformity in matrix for both series of the standards are better than 3%. (authors)
Additional details
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 41
- Journal Issue
- 2
- Journal Page Range
- p. 248-251
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 39043774
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION; S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Descriptors DEI
- ACCURACY; CALIBRATION STANDARDS; GAMMA RADIATION; NONDESTRUCTIVE ANALYSIS; PLUTONIUM; PLUTONIUM DIOXIDE; URANIUM; URANIUM OXIDES U3O8
- Descriptors DEC
- ACTINIDE COMPOUNDS; ACTINIDES; CHALCOGENIDES; CHEMICAL ANALYSIS; ELECTROMAGNETIC RADIATION; ELEMENTS; IONIZING RADIATIONS; METALS; OXIDES; OXYGEN COMPOUNDS; PLUTONIUM COMPOUNDS; PLUTONIUM OXIDES; RADIATIONS; STANDARDS; TRANSURANIUM COMPOUNDS; TRANSURANIUM ELEMENTS; URANIUM COMPOUNDS; URANIUM OXIDES
Optional Information
- Notes
- 4 figs., 2 tabs., 4 refs.