Published January 2005 | Version v1
Journal article

The particle identification detectors in accelerator mass spectrometry

  • 1. China Inst. of Atomic Energy, Beijing (China). Dept. of Nuclear Physics
  • 2. Guangxi Univ., Nanning (China). Physics Science and Engineering Technology Department

Description

The TOF, multi-anode gas ionization chamber, Bragg and X-ray detectors in accelerator mass spectrometry are described. The time, ΔE and E signals obtained from these detectors have been use for particle identification. The applications and the experimental results by using these detector systems in HI-13 tandem AMS facility have been introduced in details. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
25
Journal Issue
1
Journal Page Range
p. 8-12
ISSN
0258-0934

Optional Information

Notes
7 figs., 1 tab., 15 refs.