First application of dynamic infrared imaging in boron neutron capture therapy for cutaneous malignant melanoma
- 1. Universidad Favaloro, Solis 453, 1078 Buenos Aires (Argentina)
- 2. Departamento de Instrumentacion y Control, Comision Nacional de Energia Atomica, Avenida del Libertador 8250, 1429 Buenos Aires (Argentina) and CONICET, Avenida Rivadavia 1917, 1033 Buenos Aires (Argentina)
- 3. Departamento de Instrumentacion y Control, Comision Nacional de Energia Atomica, Avenida del Libertador 8250, 1429 Buenos Aires (Argentina)
Description
Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). In order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.
Additional details
Identifiers
- DOI
- 10.1118/1.3218760;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 36
- Journal Issue
- 10
- Journal Page Range
- p. 4519-4529
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44059876
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BORON; CLINICAL TRIALS; IMAGES; INFORMATION; INFRARED THERMOGRAPHY; MELANOMAS; NEUTRON CAPTURE THERAPY; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; SKIN; THREE-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- BODY; CARCINOMAS; DISEASES; DOSES; ELEMENTS; EPITHELIOMAS; MEASURING METHODS; MEDICINE; NEOPLASMS; NEUTRON THERAPY; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RADIOTHERAPY; SEMIMETALS; TESTING; THERAPY; THERMOGRAPHY
Optional Information
- Notes
- (c) 2009 American Association of Physicists in Medicine