Addendum to NuMI shielding assessment
Description
The original safety assessment and the Safety Envelope for the NuMI beam line corresponds to 400 kW of beam power. The Main Injector is currently capable of and approved for producing 500 kW of beam power2. However, operation of the NuMI beam line at 400 kW of power brings up the possibility of an occasional excursion above 400 kW due to better than usual tuning in one of the machines upstream of the NuMI beam line. An excursion above the DOE approved Safety Envelope will constitute a safety violation. The purpose of this addendum is to evaluate the radiological issues and modifications required to operate the NuMI beam line at 500 kW. This upgrade will allow 400 kW operations with a reasonable safety margin. Configuration of the NuMI beam line, boundaries, safety system and the methodologies used for the calculations are as described in the original NuMI SAD. While most of the calculations presented in the original shielding assessment were based on Monte Carlo simulations, which were based on the design geometries, most of the results presented in this addendum are based on the measurements conducted by the AD ES and H radiation safety group
Availability note (English)
Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?tm-2416.pdf; PURL: https://www.osti.gov/servlets/purl/939438-XRW1WI/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 18 p.
- Report number
- FERMILAB-TM--2416-ESH
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 40003733
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- CONFIGURATION; DESIGN; MODIFICATIONS; RADIATION PROTECTION; SAFETY; SAFETY MARGINS; SHIELDING; TUNING
Optional Information
- Contract/Grant/Project number
- AC02-76CH03000
- Notes
- doi 10.2172/939438
- Funding organization
- US Department of Energy (United States)