Published October 1, 2007 | Version v1
Report

Addendum to NuMI shielding assessment

Description

The original safety assessment and the Safety Envelope for the NuMI beam line corresponds to 400 kW of beam power. The Main Injector is currently capable of and approved for producing 500 kW of beam power2. However, operation of the NuMI beam line at 400 kW of power brings up the possibility of an occasional excursion above 400 kW due to better than usual tuning in one of the machines upstream of the NuMI beam line. An excursion above the DOE approved Safety Envelope will constitute a safety violation. The purpose of this addendum is to evaluate the radiological issues and modifications required to operate the NuMI beam line at 500 kW. This upgrade will allow 400 kW operations with a reasonable safety margin. Configuration of the NuMI beam line, boundaries, safety system and the methodologies used for the calculations are as described in the original NuMI SAD. While most of the calculations presented in the original shielding assessment were based on Monte Carlo simulations, which were based on the design geometries, most of the results presented in this addendum are based on the measurements conducted by the AD ES and H radiation safety group

Availability note (English)

Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?tm-2416.pdf; PURL: https://www.osti.gov/servlets/purl/939438-XRW1WI/

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
FERMILAB-TM--2416-ESH

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
40003733
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
CONFIGURATION; DESIGN; MODIFICATIONS; RADIATION PROTECTION; SAFETY; SAFETY MARGINS; SHIELDING; TUNING

Optional Information

Contract/Grant/Project number
AC02-76CH03000
Notes
doi 10.2172/939438
Funding organization
US Department of Energy (United States)