A study on the characteristics and design methodology of the regional overpower protection trip (ROPT) system in the 600 MWe CANDU reactors
- 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
Description
This report outlines the means which protects the reactor against fuel channel overpower resulting from local power transients such as a temporary Loss of Regulation incident during normal operation. This report also describes the design approach and concepts which optimize the protection and improve plant operability. Finally the reports relates the design process which conceptually shows how to determine the trip setpoints, and locations of in-core flux detectors inside the reactor and their trip channelization. 17 figs., 7 tabs., 13 refs. (Author)
Availability note (English)
MF available from INIS under the Report Number.Files
27015697.pdf
Files
(2.2 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:9c748a7b55c5ba4e37c6e683c6e6ec6c
|
2.2 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 63 p.
- Report number
- KAERI-AR--393/94
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 27015697
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CANDU TYPE REACTORS; FUEL CHANNELS; NEUTRON DETECTORS; NEUTRON FLUX; PROBABILISTIC ESTIMATION; REACTOR CONTROL SYSTEMS; REACTOR PROTECTION SYSTEMS; REACTOR SHUTDOWN
- Descriptors DEC
- CONTROL SYSTEMS; ENGINEERED SAFETY SYSTEMS; HEAVY WATER MODERATED REACTORS; MEASURING INSTRUMENTS; POWER REACTORS; PRESSURE TUBE REACTORS; RADIATION DETECTORS; RADIATION FLUX; REACTOR CHANNELS; REACTOR COMPONENTS; REACTORS; SHUTDOWN; THERMAL REACTORS