Published January 2021 | Version v1
Journal article

Predicting the thermal hysteresis behavior for a single-layer MnFeP1−xSix active magnetic regenerator

  • 1. Department of Mechanical Engineering, Institute for Integrated Energy Systems, University of Victoria, 3800 Finnerty Rd, Victoria, B.C., V8W 3P6 (Canada)
  • 2. Department of Mechanical Engineering, Federal University of Minas Gerais (UFMG), Belo Horizonte, MG, 31270-901 (Brazil)

Description

Highlights: • A model including hysteresis was implemented and used to simulate MnFeP1−xSix AMRs. • Experimental data validate the incorporation of the hysteresis in AMR models. • Results show the impact on simulated temperature spans when thermal hysteresis is included. • Magnetic hysteresis has a smaller contribution than adiabatic temperature change on MnFeP1−xSix AMR performance. Magnetocaloric materials with first-order magnetic (FOM) phase transitions are of interest as low-cost working materials in magnetic heat pumping cycles. Hysteresis is a property associated with first order transitions, and is undesirable as it can reduce the cycle performance. Devices using first-order materials in active magnetic refrigeration have shown performance comparable to more expensive second-order materials so some degree of hysteresis appears to be acceptable; however, the amount of hysteresis that may be tolerated is still an unanswered question. A one dimensional active magnetic regenerator (AMR) model accounting for thermal and magnetic hysteresis is developed and compared to experimental data for both a Gadolinium (Gd) and MnFeP1−xSix active magnetic regenerator. Magnetic and thermal hysteresis are quantified using measured data for magnetization and specific heat under isothermal and isofield warming and cooling processes. Numerical results for temperature span as a function of cooling power and rejection temperature show good agreement with experimental data. The irreversible work due to hysteresis has a small impact on predicted spans as compared to the deviation between experimental data and model predictions. This indicates useful cooling power is well predicted using cyclic measurements of adiabatic temperature change and disregarding hysteresis.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.applthermaleng.2020.116173

Additional details

Identifiers

DOI
10.1016/j.applthermaleng.2020.116173;
PII
S135943112033653X;

Publishing Information

Journal Title
Applied Thermal Engineering
Journal Volume
183
Journal Page Range
vp.
ISSN
1359-4311
CODEN
ATENFT

INIS

Optional Information

Copyright
Copyright (c) 2020 Elsevier Ltd. All rights reserved.