A movable boundary model for once-through steam generator analysis
Creators
- 1. Argonne National Lab., Reactor Analysis and Safety Div., 9700 South Cass Avenue, Argonne, IL (USA)
Description
A method was developed for the analysis of a once-through steam generator that is based on a multinode movable boundary formulation and an accurate description of the departure from nucleate boiling boundary. In the development of this method, a liquid-metal reactor steam generator was used as a reference design. To evaluate its performance, the Energy Technology Engineering Center steam generator shutdown experiment in the once-through mode was analyzed. Also, the predictions of this method were compared with those of another steam generator code. These analyses showed that the predictions of this methodology agree very well with the experimental measurements and the predictions of the other code. The maximum difference between the temperatures predicted by this model and measurements was --5 K
Additional details
Publishing Information
- Journal Title
- Nuclear Technology
- Journal Volume
- 82
- Journal Issue
- 1
- Series
- Nucl. Technol.
- Journal Page Range
- 5-20
- ISSN
- 0029-5450
- CODEN
- NUTYB
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20027064
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- ALGORITHMS; COMPUTER CODES; COOLING SYSTEMS; DEPARTURE NUCLEATE BOILING; EXPERIMENTAL DATA; LIQUID METAL COOLED REACTORS; PERFORMANCE TESTING; SPECIFICATIONS; STEAM GENERATORS
- Descriptors DEC
- BOILERS; BOILING; DATA; INFORMATION; NUCLEATE BOILING; NUMERICAL DATA; PHASE TRANSFORMATIONS; REACTORS; TESTING; VAPOR GENERATORS