External beam radiation therapy reduces the rate of re-stenosis in patients treated with femoral stenting: results of a randomised study
Creators
- 1. Department of Radiology, University Hospital of Patras Medical School, 265 00 Patras (Greece)
- 2. Department of Radiotherapy, University of Patras Medical School, 265 00 Patras (Greece)
- 3. Department of Medical Physics, University Hospital of Patras Medical School, 265 00 Patras (Greece)
Description
Background and purpose: To evaluate the feasibility and efficacy of external beam irradiation (EBI) for the prevention of re-stenosis due to neointimal hyperplasia, after percutaneous transluminal angioplasty (PTA) and stent placement of the superficial femoral artery. Patients and methods: A total of 60 patients with the diagnosis of superficial femoral artery stenoses or occlusions due to peripheral arterial obstructive disease underwent PTA and implantation of a self-expandable stent at their superficial femoral artery. After the procedure, patients were randomised and 30 of them received EBI (6 MV photons, total dose 24 Gy in six fractions in 2 weeks), while the rest 30 received no radiation therapy. Results: EBI was technically feasible in all patients, without serious radiation related side effects. Overall, a statistically significant difference was observed in stenosis categories between the two groups at 6 months follow-up (P=0.04). More specifically, significantly more patients in the control group presented with stenosis greater or equal than 70% [EBI group 30% (9/30); control group 66.7% (20/30); P=0.009]. This difference in the percentage of re-stenosis had as a consequence significantly lower re-intervention rates among the patients of the irradiated group [17% (5/30) versus 47% (14/30); P=0.025] during the 6 months follow-up period. We also observed that the irradiated patients had re-stenosis at the stent ends, while the non-irradiated had re-stenosis at the stent ends and the lumen. Three of the irradiated patients, who discontinued the anti-platelet treatment, have shown thrombosis of the irradiated artery during the first month from the completion of the treatment. Conclusions: It is our belief that EBI is a feasible, safe and effective method for the prevention of neointimal hyperplasia at the superficial femoral artery. Further studies are deemed necessary to optimise the radiotherapy schedule
Additional details
Identifiers
- DOI
- 10.1016/j.radonc.2004.09.010;
- PII
- S0167-8140(04)00450-5;
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 74
- Journal Issue
- 1
- Journal Page Range
- p. 11-16
- ISSN
- 0167-8140
- CODEN
- RAONDT
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 36074474
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; DIAGNOSIS; IRRADIATION; PATIENTS; PHOTON BEAMS; RADIATION DOSES; RADIOTHERAPY; SIDE EFFECTS; THROMBOSIS
- Descriptors DEC
- BEAMS; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DISEASES; DOSES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; VASCULAR DISEASES
Optional Information
- Copyright
- Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.