Published November 1, 2014 | Version v1
Journal article

Proton injector acceptance tests for a Dielectric Wall Accelerator (DWA):characterisation of Advanced Injection System of Light Ions (AISLI)

Description

To demonstrate the acceleration capability of a Dielectric Wall Accelerator (DWA), a proton injector has been developed at Peking University (PKU). It is composed of a compact permanent magnet 2.45 GHz Electron Cyclotron Resonance Ion Source (PKU PMECRIS) associated with a LEBT of two electrostatic Einzel lenses [1]. This injector is named as Advanced Injector System of Light Ions (AISLI). The acceptance tests have been performed with a 40 keV–55 mA hydrogen beam successfully passing through a ϕ 10 mm aperture diaphragm. This diaphragm is located 200 mm downstream the plasma emission hole at the location of the future DWA entrance flange. The beam rms emittance reached about 0.10 π mm mrad in pulsed mode. This article describes the AISLI experimental setup, the measurement principle and the obtained beam characteristics

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2014.06.025

Additional details

Identifiers

DOI
10.1016/j.nima.2014.06.025;
PII
S0168-9002(14)00732-3;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
763
Journal Page Range
p. 120-123
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.