Experimental Study on Welded Headed Studs Used In Steel Plate-Concrete Composite Structures Compared with Contactless Method of Measuring Displacement

  • 1. Department of Civil Engineering, Cracow University of Technology, Cracow (Poland)

Description

Steel plate-concrete composite structures are a new innovative design concept in which a thin steel plate is attached to the reinforced concrete beam by means of welded headed studs. The comparison between experimental studies and theoretical analysis of this type of structures shows that their behaviour is dependent on the load-slip relationship of the shear connectors used to ensure sufficient bond between the concrete and steel parts of the structure. The aim of this paper is to describe an experimental study on headed studs used in steel plate-concrete composite structures. Push-out tests were carried out to investigate the behaviour of shear connectors. The test specimens were prepared according to standard push-out tests, however, instead of I-beam, a steel plate 16 mm thick was used to better reflect the conditions in the real structure. The test specimens were produced in two batches using concrete with significantly different compressive strength. The experimental study was carried out on twelve specimens. Besides the traditional measurements based on LVDT sensors, optical measurements based on the digital image correlation method (DIC) and pattern tracking methods were used. DIC is a full-field contactless optical method for measuring displacements in experimental testing, based on the correlation of the digital images taken during test execution. With respect to conventional methods, optical measurements offer a wider scope of results and can give more information about the material or construction behaviour during the test. The ultimate load capacity and load-slip curves obtained from the experiments were compared with the values calculated based on Eurocodes, American and Chinese design specifications. It was observed that the use of the relationships developed for the traditional steel-concrete composite structures is justified in the case of ultimate load capacity of shear connectors in steel plate-concrete composite structures. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1757-899X/245/3/032026

Additional details

Publishing Information

Journal Title
IOP Conference Series. Materials Science and Engineering (Online)
Journal Volume
245
Journal Issue
3
Journal Page Range
[10 p.]
ISSN
1757-899X

Conference

Title
World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium - WMCAUS
Dates
12-16 Jun 2017
Place
Prague (Czech Republic)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52053003
Subject category
S42: ENGINEERING; S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPRESSION STRENGTH; FASTENERS; REINFORCED CONCRETE; SENSORS; SHEAR; SPECIFICATIONS; STEELS; TESTING; WELDED JOINTS
Descriptors DEC
ALLOYS; BUILDING MATERIALS; CARBON ADDITIONS; COMPOSITE MATERIALS; CONCRETES; IRON ALLOYS; IRON BASE ALLOYS; JOINTS; MATERIALS; MECHANICAL PROPERTIES; REINFORCED MATERIALS; TRANSITION ELEMENT ALLOYS