Published June 1998
| Version v1
Journal article
Pulse height of MIP's in an n-side silicon microstrip detector after proton irradiation with a fluence of 1 x 1015 p cm-2
Creators
- 1. Univ. of California, Santa Cruz, CA (United States)
Description
Plans for a pixel detector in ATLAS at the LHC anticipate a total fluence of about 1015 p cm-2. This is about ten times higher than for the silicon strip detectors. Here, the authors have irradiated an n-side silicon microstrip detector to an equivalent high energy fluence of 1 x 1015 p cm-2 using 55 MeV protons. They determined the median pulse height to be 0.7 fC at a bias voltage of 180 V, and deduced a depletion region of about 80 microm
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 45
- Journal Issue
- 3Pt1
- Journal Page Range
- p. 327-330
- ISSN
- 0018-9499
- CODEN
- IETNAE
Conference
- Title
- Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference
- Dates
- 11-13 Nov 1997
- Place
- Albuquerque, NM (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 29048208
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DEPLETION LAYER; N-TYPE CONDUCTORS; PHYSICAL RADIATION EFFECTS; PROTON BEAMS; SI SEMICONDUCTOR DETECTORS
- Descriptors DEC
- BEAMS; MATERIALS; MEASURING INSTRUMENTS; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DETECTORS; RADIATION EFFECTS; SEMICONDUCTOR DETECTORS; SEMICONDUCTOR MATERIALS
Optional Information
- Secondary number(s)
- CONF-971147--