Published 2002 | Version v1
Book

Major Component Replacement Experience in IKATA Power Station

Description

Unit 1 and 2 in IKATA power station, both are two-loop PWRs, have experienced major component replacement. The components are two steam generators (SG) and a reactor pressure vessel closure head (VH) for each plant and were replaced with improved ones. This paper explains the reasons for the replacement and major improvements in the components. (authors)

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers - ASME
Imprint Place
New York (United States)
Imprint Pagination
5 p.

Conference

Title
10. international conference on nuclear engineering - ICONE 10
Dates
14-18 Apr 2002
Place
Arlington - Virginia (United States)

INIS

Country of Publication
United States
Country of Input or Organization
France
INIS RN
39084285
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CLOSURES; IKATA REACTOR; IKATA-2 REACTOR; PRESSURE VESSELS; STEAM GENERATORS
Descriptors DEC
BOILERS; CONTAINERS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS