Published December 2016 | Version v1
Journal article

Evaluation of hospital radiopharmacy-based 68Ga-labeled radiopharmaceutical: 68Ga-HBEDCC-PSMA-11

  • 1. Department of Nuclear Medicine and Molecular Imaging, Tata Memorial Hospital, Mumbai (India)

Description

Development of 68Ge/ 68Ga generator system boosted development of 68-gallium-labeled radiopharmaceuticals. Recent development is use of nonmetallic silica-based adsorbed resin column. Its advantage is eluate with minimal metallic impurities, which improves labeling efficiency of 68-Ga-labeled radiopharmaceuticals. Introduction of 68Ga-HBED-CC-PSMA ushered a new path in detection and staging of prostate cancer in PET-CT imaging. We performed labeling procedure of 68Ga-PSMA-11 using eluate of nonmetallic 68Ge/ 68Ga generator. 5 µg of peptide (DKFZ-PSMA-11) in 900 µl of 0.25 M sodium acetate buffer was used for labeling. We performed 175 labeling procedures in a span of 14 months using two generators (n = 105 I st generator, n = 70 II nd generator). Elution was done using 4 ml of 0.05 M HCl. After heating for 5 min at 1000°C, labeled product was passed through C18 cartridge. Impurities were collected in waste vial. Extraction was done using ethanol. pH of waste and product was measured. Radiochemical purity of 68Ga-PSMA-11 was determined by instant thin-layer chromatography method using silica adsorbed Al stripes and 0.1 M tri-sodium acetate, (1:1) acetonitrile:water as a solvent. Its stability was evaluated after 2 h. pH of product 68Ga-PSMA-11 was shown as 5.5 and for waste as 4.0. We calculated labeling efficiency of 68Ga-labeled product using both generators. Using first generator labeling efficiency of 68Ga-PSMA-11 was 78%. Using second generator labeling efficiency of 68Ga-PSMA was 79%. Radiochemical purity of labeled product was >98%. The product showed good stability over a period of 2 h as radiochemical purity was above 94%. ITG 68Ge/ 68Ga generator system showed high radiochemical yield of 68Ga-HBED-CC-PSMA-11. We observed consistency in labeling efficiency of both generators. High radiochemical purity and stability of the labeled product ascertained its use as reliable radiopharmaceutical in diagnosis and staging of prostate cancer. (author)

Additional details

Publishing Information

Journal Title
Indian Journal of Nuclear Medicine
Journal Volume
31
Journal Issue
5,suppl
Journal Page Range
p. 34-35
ISSN
0972-3919

Conference

Title
48. annual conference of the society of nuclear medicine, India
Acronym
SNMICON-2016
Dates
17-20 Nov 2016
Place
Ahmedabad (India)