Published May 2010 | Version v1
Journal article

Labeling of 3H11 With 123I and Its Biodistribution

  • 1. High Technology Atomic Co., LTD, Beijing (China)
  • 2. Beijing Department of Nuclear Medicine, Biejing Cancer Hospital, Peking University School of Oncology, Beijing (China)

Description

3H11 was labeled with 123I by Iodogen method,and the labeling product were purified with PD-10 column. The labeling yield and the radiochemical purity of the product was determined by paper chromatography. The biodistribution of 123I-3H11 in normal mice was car ride out as well. The optimal experimental conditions of 123I-3H11 was as follow: Iodogen 10 μg, 3H11 30 μg, Na 123I solution 20 μL (13.3 MBq), PBS 100 μL (pH 7.4, 0.2 mol/L), the normal temperature for 8 min. The labeling yield of 123I-3H11 was 70%-80%. After stored at 4 degree C for 48 h in human serum,the radiochemical purity was more than 92%. The results of biodistribution showed that the clearance of radiolabeled antibody in blood (half time, T1/2) was 12.25±0.25 h, and the radioactivity in the stomach was up taken obviously. The above results indicated that 123I-3H11 appears to show some potential as gastric cancer imaging diagnostic agent. (authors)

Additional details

Publishing Information

Journal Title
Journal of Isotopes
Journal Volume
23
Journal Issue
2
Journal Page Range
p. 76-80
ISSN
1000-7512

Optional Information

Notes
9 figs., 1 tabs., 11 refs.