Published January 1993 | Version v1
Report Open

General vibration monitoring: Experimental hall

Description

The reported vibration data were generated from measurements made on the experimental hall floor on December 2, 1992. At the time of the measurements, the ESRF hydrolevel was set-up in the Early Assembly Area (EAA) of the experimental hall and was being used to measure static displacement (settlement) of the floor. The vibration measurement area was on and adjacent to the EAA, in the vicinity of the ESRF hydrolevel test which was in progress. This report summarizes the objectives, instrumentation, measurement locations, observations, and conclusions, and provides selected results in the form of RMS vs. time plots, and power spectral densities from which frequency information can be derived. Measured response amplitudes were within the vibration criteria established for the APS

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94001425; NTIS; US Govt. Printing Office Dep.

Files

25028717.pdf

Files (498.1 kB)

Name Size Download all
md5:25242fae740089641eea864d5f4fab34
498.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
52 p.
Report number
ANL/APS/IN/VIB--93/3

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
25028717
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ADVANCED PHOTON SOURCE; FREQUENCY DEPENDENCE; FREQUENCY RESPONSE TESTING; MECHANICAL VIBRATIONS; MONITORING
Descriptors DEC
RADIATION SOURCES; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES; TESTING

Optional Information

Contract/Grant/Project number
Contract W-31109-ENG-38
Funding organization
USDOE, Washington, DC (United States).