Published September 1981
| Version v1
Report
Restricted
Probability of pipe fracture in the primary coolant loop of a PWR plant. Volume 2: primary coolant loop model. Final report
Description
This report describes the Zion Station reactor coolant loop model developed by Sargent and Lundy Engineers for Lawrence Livermore National Laboratory as part of its Load Combination Program. This model was developed for use in performing seismic time history analyses of an actual pressurized water reactor (PWR) system. It includes all major items affecting the seismic response of a 4-loop Westinghouse nuclear steam supply system: the components, supports, and interconnecting piping. The model was further expanded to permit static analysis of dead weight, thermal, and internal pressure load conditions
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A07/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 150 p.
- Report number
- NUREG/CR--2189-V2
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13695977
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTERIZED SIMULATION; DYNAMIC LOADS; EARTHQUAKES; MATHEMATICAL MODELS; PIPES; PRIMARY COOLANT CIRCUITS; PROBABILITY; PWR TYPE REACTORS; RUPTURES; SEISMIC EFFECTS
- Descriptors DEC
- COOLING SYSTEMS; FAILURES; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; SIMULATION; WATER COOLED REACTORS; WATER MODERATED REACTORS