Published September 1999
| Version v1
Journal article
Vascular Access System for Continuous Arterial Infusion of a Protease Inhibitor in Acute Necrotizing Pancreatitis
Creators
- 1. Department of Radiology, Jikei University School of Medicine, Aoto Hospital, 6-41-2 Aoto, Katsushika-ku, Tokyo 125-8506 (Japan)
Description
We used a vascular access system (VAS) for continuous arterial infusion (CAI) of a protease inhibitor in two patients with acute necrotizing pancreatitis. The infusion catheter was placed into the dorsal pancreatic artery in the first patient and into the gastroduodenal artery in the second, via a femoral artery approach. An implantable port was then connected to the catheter and was secured in a subcutaneous pocket prepared in the right lower abdomen. No complications related to the VAS were encountered. This system provided safe and uncontaminated vascular access for successful CAI for acute pancreatitis
Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 22
- Journal Issue
- 5
- Journal Page Range
- p. 436-438
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39092953
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; ARTERIES; DIGESTIVE SYSTEM DISEASES; PANCREAS; PATIENTS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIGESTIVE SYSTEM; DISEASES; ENDOCRINE GLANDS; GLANDS; ORGANS
Optional Information
- Copyright
- Copyright (c) 1999 Springer-Verlag New York Inc.