Vascular Access System for Continuous Arterial Infusion of a Protease Inhibitor in Acute Necrotizing Pancreatitis

  • 1. Department of Radiology, Jikei University School of Medicine, Aoto Hospital, 6-41-2 Aoto, Katsushika-ku, Tokyo 125-8506 (Japan)

Description

We used a vascular access system (VAS) for continuous arterial infusion (CAI) of a protease inhibitor in two patients with acute necrotizing pancreatitis. The infusion catheter was placed into the dorsal pancreatic artery in the first patient and into the gastroduodenal artery in the second, via a femoral artery approach. An implantable port was then connected to the catheter and was secured in a subcutaneous pocket prepared in the right lower abdomen. No complications related to the VAS were encountered. This system provided safe and uncontaminated vascular access for successful CAI for acute pancreatitis