Published 1990 | Version v1
Book

Pressure drop of He II flow through a porous media

  • 1. Fermi National Accelerator Laboratory, Batavia, IL (United States)

Description

The paper reports on measurements of He II pressure drop across two porous SiO2 ceramic filter materials. These materials vary only in porosity, having values of 0.94 and 0.96. The average fiber diameter in both cases is approximately 5 microns. The experiment consists of a glass tube containing a piece of this sponge in one end. The tube is rapidly displaced downward in a bath of helium and the liquid levels are allowed to equilibrate over time producing variable velocities up to 10 cm/sec. The results are compared with those previously obtained using fine mesh screens. Good qualitative agreement is observed for turbulent flow; however, the behavior in the laminar flow regime is not fully understood. 3 refs

Additional details

Publishing Information

Publisher
Inc., U.S. Navy, NASA, et al. New York, Plenum Press.
Imprint Place
New York, NY (United States)
Imprint Title
Advances in cryogenic engineering. Vols. 35A ampersand 35B - Proceedings of the 1989 Cryogenic Engineering Conference, University of California, Los Angeles, July 24-28, 1989
Imprint Pagination
vp.
Journal Page Range
p. 189-195.

Conference

Title
International cryogenic materials conference.
Dates
24-28 Jul 1989.
Place
Los Angeles, CA (United States).

Optional Information

Notes
Imprint:927.
Secondary number(s)