Analytical determination of selenium in medical samples, staple food and dietary supplements by means of total reflection X-ray fluorescence spectroscopy
Creators
Description
Selenium is essential for many aspects of human health and, thus, the object of intensive medical research. This demands the use of analytical techniques capable of analysing selenium at low concentrations with high accuracy in widespread matrices and sometimes smallest sample amounts. In connection with the increasing importance of selenium, there is a need for rapid and simple on-site (or near-to-site) selenium analysis in food basics like wheat at processing and production sites, as well as for the analysis of this element in dietary supplements. Common analytical techniques like electrothermal atomic absorption spectroscopy (ETAAS) and inductively-coupled plasma mass spectrometry (ICP-MS) are capable of analysing selenium in medical samples with detection limits in the range from 0.02 to 0.7 μg/l. Since in many cases less complicated and expensive analytical techniques are required, TXRF has been tested regarding its suitability for selenium analysis in different medical, food basics and dietary supplement samples applying most simple sample preparation techniques. The reported results indicate that the accurate analysis of selenium in all sample types is possible. The detection limits of TXRF are in the range from 7 to 12 μg/l for medical samples and 0.1 to 0.2 mg/kg for food basics and dietary supplements. Although this sensitivity is low compared to established techniques, it is sufficient for the physiological concentrations of selenium in the investigated samples.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.sab.2010.07.001Additional details
Identifiers
- DOI
- 10.1016/j.sab.2010.07.001;
- PII
- S0584-8547(10)00208-9;
Publishing Information
- Journal Title
- Spectrochimica Acta. Part B, Atomic Spectroscopy
- Journal Volume
- 65
- Journal Issue
- 9-10
- Journal Page Range
- p. 859-863
- ISSN
- 0584-8547
- CODEN
- SAASBH
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42013555
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ABSORPTION SPECTROSCOPY; ICP MASS SPECTROSCOPY; REFLECTION; SAMPLE PREPARATION; SELENIUM; SENSITIVITY; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- CHEMICAL ANALYSIS; ELEMENTS; MASS SPECTROSCOPY; NONDESTRUCTIVE ANALYSIS; SEMIMETALS; SPECTROSCOPY; X-RAY EMISSION ANALYSIS