Postmastectomy radiation therapy using VMAT technique for breast cancer patients with expander reconstruction
Creators
- De Rose, Fiorenza1
- Fogliata, Antonella1
- Franceschini, Davide1
- Cozzi, Salvatore1
- Iftode, Cristina1
- Stravato, Antonella1
- Tomatis, Stefano1
- Masci, Giovanna2
- Torrisi, Rosalba2
- Testori, Alberto3
- Tinterri, Corrado3
- Lisa, Andrea V. E.4
- Maione, Luca4
- Vinci, Valeriano4
- Klinger, Marco4
- Santoro, Armando2
- Scorsetti, Marta1
- 1. Humanitas Research Hospital, Radiotherapy and Radiosurgery Department (Italy)
- 2. Humanitas Research Hospital, Medical Oncology Department (Italy)
- 3. Humanitas Research Hospital, Breast Surgery Department (Italy)
- 4. Humanitas Research Hospital, Plastic Surgery Department (Italy)
Description
Postmastectomy radiotherapy (PMRT) following immediate breast reconstruction is increasingly adopted in the management of breast cancer patients. We retrospectively evaluate the complication rates of PMRT using VMAT technique to immediate tissue expander-based reconstructions and the possible impact of tissue expander volume on radiotherapy planning. We reviewed the data of patients who underwent immediate expander breast reconstruction and received PMRT with VMAT (50 Gy in 25 fractions) on the reconstructed breast and axillary levels III–IV. Neoadjuvant or adjuvant systemic therapy was administered in most of the patients. Autologous fat grafting was routinely performed at the time of second-stage reconstruction. Between 2015 and 2017, PMRT was delivered to 46 consecutive patients (median age 50 years) with expander reconstruction. Median follow-up was 27 months (range 10–41). Two patients (4.3%) had a reconstruction failure, as expander rupture and infection, following the first- and the second-stage reconstruction, respectively. In most cases expanders were completely inflated before PMRT (65.2%). Median expander volume before PMRT was 425 cm3 (range 150–700 cm3). The amount of expander inflation did not significantly affect dosimetry, except for skin dose, with a surface receiving more than 30 Gy of 36.6 ± 0.9 cm2 and 47.0 ± 2.5 cm2 for a volume expander below or above the median, respectively. However, this variable was not predictor for complications. Disease progression was recorded in 15.2% of patients. PMRT using VMAT technique for breast cancer patients with expander reconstruction is associated with a very low complication rate. The expander volume before PMRT does not significantly compromise radiotherapy dose distribution.
Additional details
Identifiers
Publishing Information
- Journal Title
- Medical Oncology (Online)
- Journal Volume
- 36
- Journal Issue
- 6
- Journal Page Range
- p. 1-8
- ISSN
- 1559-131X
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51102473
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DOSIMETRY; MAMMARY GLANDS; NEOPLASMS; PATIENTS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; RUPTURES; SKIN
- Descriptors DEC
- BODY; DISEASES; FAILURES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY
Optional Information
- Copyright
- Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature
- Notes
- http://www.springer-ny.com