A NE-213 Liquid scintillator, neutron detector designed for lifetime measurements of very neutron-rich nuclei

  • 1. Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire
  • 2. Bordeaux-1 Univ., 83 - Gradignan (France). Centre d'Etudes Nucleaires
  • 3. Goettingen Univ. (Germany, F.R.). Inst. fuer Physikalische Chemie

Description

The design and construction of a coincidence detector destined for lifetime and delayed-neutron emission probability measurements is discussed. Its operating in the context of the LISE spectrometer at the GANIL facility is described. Results are given which illustrate the performance and reliability of this detector

Availability note (English)

MF available from INIS under the Report Number.

Files

20057482.pdf

Files (442.4 kB)

Name Size Download all
md5:cc71e9affa5dfab18ff370b399453252
442.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
31 p.
Report number
GANIL-P--89-01