Published 1979 | Version v1
Report Open

Measurement of the thickness and homogeneity of thin foils by slowing down alpha particles

Description

The energy loss of 8.785 MeV α particles passing through a thin foil is used to measure the foil thickness. The measurement is performed in various points of the target, the abscissa and ordinate of which are set with precision from the outside of the chamber. This gives a thickness map of the target. The working up of the data, and the use of energy loss tables are made in a standard way. The absolute uncertainty is of some percent for 100 μg/cm2 foils. The technique has been refined to reach the same precision for 10 μg/cm2 targets

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

La mesure du ralentissement de particules α de 8.785 MeV est utilisee pour acceder a l'epaisseur de cibles solides. Cette epaisseur est mesuree en des points bien precis, reperes en X et Y depuis l'exterieur de la chambre. On peut ainsi etablir une veritable carte d'epaisseur de chaque feuille. Le depouillement des donnees et l'utilisation des tables de ralentissement sont standardises. On atteint une precision de quelques pour cent sur les epaisseurs absolues, pour des epaisseurs de l'ordre de 100 μg/cm2. La methode a ete amelioree pour l'etendre aux faibles epaisseurs et appliquee a des feuilles d'environ 10 μg/cm2, avec une precision du meme ordre

Files

11520063.pdf

Files (371.2 kB)

Name Size Download all
md5:2f721413de663e4993ef91dce2074c82
371.2 kB Preview Download

Additional details

Additional titles

Original title (French)
Mesure de l'epaisseur de l'homogeneite de feuilles minces par ralentissement de particles α

Publishing Information

Imprint Pagination
21 p.
Report number
IPNO-RC--79-06

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
11520063
Subject category
S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
ALPHA PARTICLES; ENERGY LOSSES; EXPERIMENTAL DATA; FOILS; GRAPHS; SLOWING-DOWN; TABLES; TARGETS; THICKNESS
Descriptors DEC
CHARGED PARTICLES; DATA; DATA FORMS; DIMENSIONS; HELIUM IONS; INFORMATION; IONS; NUMERICAL DATA