Published March 1981 | Version v1
Report

Reconnection conditions for flowing field-reversed plasma from a plasma gun

  • 1. Lawrence Livermore Lab., CA

Description

Although various theoretical models are known for magnetic reconnection, none of them are applicable to the BETA-II experiment because they do not model the plasma flow conditions. The coaxial gun produces a plasma stream with an axial velocity of approx. 108 cm/sec. In the plasma rest frame an aperture or snipper coil would appear to move in the opposite direction at this same velocity. A more suitable model for the BETA-II reconnection problem was formulated based on the equations of fluid flow through a nozzle

Additional details

Publishing Information

Imprint Title
Proceedings on the US-Japan joint symposium on compact toruses and energetic particle injection
Journal Page Range
p. 61-64.
Report number
PPPL--1755

Conference

Title
Symposium on compact toruses and energetic particle injection.
Dates
11 - 14 Dec 1979.
Place
Princeton, NJ, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12625919
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
MAGNETIC FIELD CONFIGURATIONS; MAGNETIC FIELD REVERSAL; MATHEMATICAL MODELS; PLASMA BEAM INJECTION; PLASMA GUNS; 2X DEVICES
Descriptors DEC
BEAM INJECTION; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; THERMONUCLEAR DEVICES