Effects of grid potentials and geometric dimensions on the multi-electrode probe measurements
Creators
- 1. Cairo Univ., El Mansura (Egypt). Faculty of Science
- 2. Al-Azhar Univ., Cairo (Egypt). Faculty of Science
Description
A hollow anode plasma source is used to produce low temperature plasma which is injected into a magnetic field. The effects of the grid potentials, collector potential and geometric dimensions on multi-electrode probe measurements, in the presence of a magnetic field, are investigated. It is found that the collector potential plays a substantial role in the measurement of temperatures and densities. The finite-size of the geometric dimensions of the probe influences the data and high values of temperature are obtained when a small ratio of the discriminator grid radius to the separation distance is used, providing that the repeller grid potentials is low. Reliable measurements can only be obtained if the multi-electrode probe is used in the presence of a magnetic field strong enough to reduce electron Larmor radii to less than the grid mesh radius. (author)
Additional details
Publishing Information
- Journal Title
- J. Fiz. Malays.
- Journal Volume
- 7
- Journal Issue
- 3
- Series
- J. Fiz. Malays.
- Journal Page Range
- 111-118
- ISSN
- 0126-9674
- CODEN
- JFMAE
INIS
- Country of Publication
- Malaysia
- Country of Input or Organization
- Malaysia
- INIS RN
- 19029767
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ANODES; DIMENSIONS; ELECTRIC POTENTIAL; ELECTRIC PROBES; ELECTRON TEMPERATURE; GRIDS; ION TEMPERATURE; MAGNETIC FIELDS; PLASMA DENSITY; TEMPERATURE MEASUREMENT
- Descriptors DEC
- ELECTRODES; PROBES