Published October 2019 | Version v1
Journal article

Measurements of cosmic ray induced background neutrons near the ground using a Bonner sphere spectrometer

  • 1. Department of Physics, University of Milan-Bicocca, Milan 20126 (Italy)
  • 2. School of Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China)
  • 3. Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China)

Description

This report documents measurements of cosmic ray induced background neutrons using a new Bonner sphere spectrometer (BSS) based on a 3He thermal neutron counter (SP9 type). Three spheres with a lead or copper layer were added to a BSS to enhance its sensitivity in the high-energy range above 20 MeV and enable the spectrometer to cover the entire energy range from thermal to multi-GeV. The response function of the spectrometer was calculated using the Monte Carlo code MCNP6. Below 20 MeV, the responses of polyethylene spheres were experimentally verified with 6 mono-energetic neutron sources. A neutron spectrum was measured near the ground at one location in Beijing. Also deduced from the spectrum were the rates of neutron fluence, ambient dose equivalent, and effective dose.

Additional details

Identifiers

DOI
10.1016/j.nima.2019.06.004;
PII
S0168900219308216;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
940
Journal Page Range
p. 78-82
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2019 Published by Elsevier B.V.