Published June 2006
| Version v1
Journal article
Misreading of pressure measurement by radiation, and its measures
Creators
- 1. Japan Synchrotron Radiation Research Institute, Sayo, Hyogo (Japan)
Description
In the SPring-8 Storage Ring, the pressure measured by Bayard-Alpert gauge near photon-absorber were not observed aging effects by a beam self-cleaning. As the result of investigations of this phenomenon, three causes of misreading of pressure measurement were found; (1) irradiation of the scattered X-ray to gauge head, (2) a large amount of electronic inflow to gauge head, (3) irradiation of the scattered X-ray to gauge cable. We took measures to the misreading, for example shielding of gauge heads and cables etc, and came to be able to measure pressure within tens of percent errors. (author)
Additional details
Publishing Information
- Journal Title
- Shinku
- Journal Volume
- 49
- Journal Issue
- 5
- Journal Page Range
- p. 302-305
- ISSN
- 0559-8516
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 37082442
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BAYARD-ALPERT GAGES; CABLES; ERRORS; IONS; PRESSURE MEASUREMENT; RADIATION EFFECTS; SHIELDING; SPRING-8 STORAGE RING; SYNCHROTRON RADIATION; VACUUM SYSTEMS; X RADIATION
- Descriptors DEC
- BREMSSTRAHLUNG; CHARGED PARTICLES; ELECTROMAGNETIC RADIATION; IONIZATION GAGES; IONIZING RADIATIONS; MEASURING INSTRUMENTS; PRESSURE GAGES; RADIATION SOURCES; RADIATIONS; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES; VACUUM GAGES
Optional Information
- Notes
- 5 refs., 7 figs.