The Physical Connection and Magnetic Coupling of the MICE Cooling Channel Magnets and the Magnet Forces for Various MICE Operating Modes
Description
A key issue in the construction of the MICE cooling channel is the magnetic forces between various elements in the cooling channel and the detector magnets. This report describes how the MICE cooling channel magnets are hooked to together so that the longitudinal magnetic forces within the cooling channel can be effectively connected to the base of the experiment. This report presents a magnetic force and stress analysis for the MICE cooling channel magnets, even when longitudinal magnetic forces as large as 700 kN (70 tons) are applied to the vacuum vessel of various magnets within the MICE channel. This report also shows that the detector magnets can be effectively separated from the central MICE cooling channel magnets without damage to either type of magnet component
Availability note (English)
Available from OSTI as DE00918478; PURL: https://www.osti.gov/servlets/purl/918478-G5o4MD/Additional details
Identifiers
Publishing Information
- Journal Title
- IEEE Transactions on Applied Superconductivity (Online)
- Journal Volume
- 17
- Journal Issue
- 2
- Journal Page Range
- vp.
- ISSN
- 1558-2515
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 39107297
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- CONSTRUCTION; COOLING; MAGNETS; MUONS; STRESS ANALYSIS
- Descriptors DEC
- ELEMENTARY PARTICLES; EQUIPMENT; FERMIONS; LEPTONS
Optional Information
- Contract/Grant/Project number
- BnR: YN0100000; AC02-05CH11231
- Notes
- Journal Publication Date: June 2007
- Funding organization
- USDOE. Office of the Chief Financial Officer. Other Costs and Credits (United States)
- Secondary number(s)
- LBNL--61385