Published September 1997 | Version v1
Journal article

Releveling and behavior of strap-retrofitted damaged test foundations exposed to mine subsidence

Creators

  • 1. Marino Engineering Associates, Inc., Champaign, IL (United States)

Description

Test foundation walls were constructed in an area of planned subsidence. These crawl space-sized block bearing walls were located in the tension zone of a longwall panel. The test walls were 1.2 m (40 ft) long and were vertically loaded on top with soil binds to simulate the weight of a house. As the longwall proceeded past these test foundations, subsidence movements damaged the test structures. These damaged foundations were then structurally and aesthetically repaired by using a steel strap retrofit and applying a cementitious surface coating. The repaired test foundations underwent significant subsequent subsidence as an adjacent longwall was mined beneath. The response of the repaired foundation is summarized in this paper. The steel straps were also used to relevel another set of the test foundations after they were tilted and damaged by subsidence. First, the straps were applied to the block bearing walls, and then wall jacks were used to lift the upper portion of the walls to a level position. This releveling procedure is outlined with the results

Additional details

Publishing Information

Journal Title
Journal of Geotechnical and Geoenvironmental Engineering
Journal Volume
123
Journal Issue
9
Journal Page Range
p. 847-855.
ISSN
1090-0241
CODEN
JGGEFK

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
28074149
Subject category
S01: COAL, LIGNITE, AND PEAT;
Descriptors DEI
COAL MINING; FOUNDATIONS; GROUND SUBSIDENCE; ILLINOIS; LONGWALL MINING; MONITORING; REPAIR; RESPONSE FUNCTIONS; WALLS
Descriptors DEC
DEVELOPED COUNTRIES; FUNCTIONS; MECHANICAL STRUCTURES; MINING; NORTH AMERICA; SUPPORTS; UNDERGROUND MINING; USA