TOP test with pre-ramp in the CABRI reactor

Description

A transient overpower (TOP) test preceded by a pre-ramp with subsequent cooling time has been carried out in the CABRI driver core. The results have demonstrated the feasibility of this type of test. The pre-ramp rate is actually limited to ≤9 cent/s according to a period limit of ≥ 10 s