Published 1980
| Version v1
Journal article
Radioisotope devices at lead concentrating works
Creators
Description
Described is the experience in application of padioisotope devices at the concentration mills of Zyryanovsk lead works where an automatic control system of technological process and production is in operation. GR-6 and GR-7 gamma-relay devices are used as level indicators in an automatic system of loading and stemming of a grinder transport route units and bunker with ore. For measuring the suspension specific mass during polymetallic ore enrichment PR-1024V radioisotope densimeter is used. Radioisotope moisture gage introduction is planned for rapid monitoring and of the humidity control of finished concentrates. The benefit is expected to be 10000 roubles for every moisture gage
Additional details
Additional titles
- Original title (Russian)
- Радиоизотопные приборы на свинцовом комбинате
Publishing Information
- Journal Title
- Izot. SSSR
- Journal Issue
- no.57
- Series
- Izot. SSSR.
- ISSN
- 0579-2940
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 12613737
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- AUTOMATION; CONTROL SYSTEMS; DENSIMETERS; EFFICIENCY; LEAD ORES; LEVEL INDICATORS; MOISTURE GAGES; ORE ENRICHMENT; POLYMETALLIC ORES; RADIOMETRIC GAGES; RELAYS
- Descriptors DEC
- ELECTRICAL EQUIPMENT; MEASURING INSTRUMENTS; ORE PROCESSING; ORES; SEPARATION PROCESSES