Evaluation of Diablo Canyon Nuclear Power Station Unit 2 Technical Specifications
Description
This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Diablo Canyon Nuclear Power Station Unit 2 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis report (FSAR) as amended, and the requirements of the Safety Evaluaton Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Diablo Canyon T/S. Several discrepancies were identified and subsequently resolved by the cognizant NRC reviewer. Pending completion of the resolutions noted in Section 3 of this report, the Diablo Canyon Nuclear Power Station Unit 2 T/S, to the extent reviewed, are in conformance with the FSAR and SER
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - GPO as TI86002321.
Files
Additional details
Publishing Information
- Imprint Pagination
- 19 p.
- Report number
- EGG-EA--6989
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17028442
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; DIABLO CANYON-2 REACTOR; SAFETY; SPECIFICATIONS
- Descriptors DEC
- ENRICHED URANIUM REACTORS; EVALUATION; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS