Published 1981
| Version v1
Journal article
Measurement of lattice spacing of nuclear graphite
Creators
Description
The method covers the measurement of the characteristic lattice space in the (00.1) and (110) crystallographic directions in nuclear graphite. A copper x-ray tube operated at 35 kV and 20 mA is recommended. A standard counter diffractometer and a standard powder camera may be used. Procedures for sampling, using the camera, using the diffractometer, and reporting the results are given
Additional details
Publishing Information
- Journal Title
- Annu. Book ASTM Stand.
- Journal Issue
- no.45
- Series
- Annu. Book ASTM Stand.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13688855
- Subject category
- S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Standard or Specification
- Descriptors DEI
- CAMERAS; COPPER; CRYSTAL LATTICES; DIFFRACTOMETERS; GRAPHITE; LATTICE PARAMETERS; NUCLEAR INDUSTRY; SAMPLING; SPECIFICATIONS; X-RAY TUBES
- Descriptors DEC
- CARBON; CRYSTAL STRUCTURE; ELECTRON TUBES; ELEMENTS; INDUSTRY; MEASURING INSTRUMENTS; METALS; NONMETALS; TRANSITION ELEMENTS; X-RAY EQUIPMENT