Published June 1983
| Version v1
Report
Immission measurement - state of the art, experience, trends
Creators
- 1. Eidgenoessische Kommission zur Ueberwachung der Radioaktivitaet (KUER), Fribourg (Switzerland)
- 2. Hahn-Meitner-Institut fuer Kernforschung Berlin G.m.b.H. (Germany, F.R.)
- 3. Oesterreichisches Forschungszentrum Seibersdorf G.m.b.H.
Description
Microprocessors have initiated enormous progress in the field of radioactivity monitoring. High-sensitivity, nuclide-specific methods of measurement and automatic sampling systems help to detect even minimum concentrations of radionuclides. In consequence, environmental radioactivity is among the best-monitored emissions. Concentration measurements in different media, including the human body, help to establish the fate of radionuclides. Even with fallout levels and emissions from modern nuclear facilities decreasing, immission monitoring in consideration of radiation protection aspects will continue to be indispensable. (orig.)
Abstract (German)
Die Radioaktivitaets-Messtechnik hat vor allem durch die Entwicklung der Elektronik und die Einfuehrung der Mikroprozessoren enorme Fortschritte gemacht. Dank den hochempfindlichen nuklidspezifischen Messverfahren und automatischen Probenahmesystemen kann heute fast jedes Nuklid auch bei geringster Konzentration in der Umwelt nachgewiesen werden. so dass die Umweltradioaktivitaet zu den bestueberwachten Immissionen gehoert. Die Konzentrationsmessungen in den verschiedenen Medien, incl. menschlichem Koerper, lassen Rueckschluesse auf die Uebergangsprozesse zu. Auch wenn der Falloutpegel in der Umwelt heute sehr tief ist und die Emissionen aus modernen kerntechnischen Anlagen klein sind, sind auch in Zukunft Immissionmessungen in angemessenem Umfang weiterzufuehren, wobei sich jedoch der messtechnische Aufwand nach den Anforderungen des Strahlenschutzes zu richten hat. (orig.)Additional details
Additional titles
- Original title (German)
- Immissionsmesstechnik - Stand, Erfahrungen und Tendenzen
Publishing Information
- Imprint Title
- Radiation protection, measurements and methods
- Imprint Pagination
- 615 p.
- Journal Page Range
- p. 325-334.
- Report number
- FS--83-30-T
Conference
- Title
- Radiation protection, measurements and methods.
- Acronym
- 16. annual meeting of the Fachverband fuer Strahlenschutz e.V.
- Dates
- 19-22 Oct 1982.
- Place
- Munich (Germany, F.R.).
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 15067430
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSIMETRY; ENVIRONMENT; NUCLEAR FACILITIES; OPERATION; RADIATION MONITORING; SWITZERLAND
- Descriptors DEC
- DEVELOPED COUNTRIES; EUROPE; MONITORING
Optional Information
- Notes
- Imprint:Strahlenschutzmesstechnik.;Tagungsbericht.
- Secondary number(s)
- GSF--A4/83.