In-plant safety/relief valve discharge load test, Monticello Plant. Final report

Description

This document reports the results of the test program of safety/relief valve (SRV) discharge load phenomena through a ramshead discharge device, and the effects upon the Mark I primary containment torus structure of the Monticello Nuclear Power Plant. The objectives were to provide a data base for verifying/improving bubble pressure, water reflood and piping load analytical models, and to measure the structural response of the torus, SRV piping, supports and acceleration of the basement and pedestal

Availability note (English)

MF available from INIS under the Report Number; General Electric Co., San Jose, CA.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
v p.
Report number
NEDC--21581

INIS