Published September 1, 1999
| Version v1
Report
Restricted
Letter report seismic shutdown system failure mode and effect analysis
Creators
Description
The Supply Ventilation System Seismic Shutdown ensures that the 234-52 building supply fans, the dry air process fans and vertical development calciner are shutdown following a seismic event. This evaluates the failure modes and determines the effects of the failure modes
Availability note (English)
Available from INIS in electronic form; Also available from OSTI as DE00798076; PURL: https://www.osti.gov/servlets/purl/798076-XI3YUe/webviewable/
Files
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 30 p.
- Report number
- HNF-SD-C--053-RPT-001/Rev.1
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 34009277
- Subject category
- S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Descriptors DEI
- BLOWERS; CALCINATION; ENGINEERED SAFETY SYSTEMS; FAILURE MODE ANALYSIS; FURNACES; SEISMIC EVENTS; SHUTDOWN; VENTILATION SYSTEMS
- Descriptors DEC
- CHEMICAL REACTIONS; DECOMPOSITION; PYROLYSIS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; THERMOCHEMICAL PROCESSES
Optional Information
- Contract/Grant/Project number
- AC06-96RL13200
- Funding organization
- ENVIRONMENTAL MANAGEMENT (United States)