Published June 2002
| Version v1
Report
Open
MELCOR Analyses of Divertor Ex-vessel LOCA During Normal Operation. Contract EFDA 01/599, Deliverable 3 - Final Report
Description
A MELCOR model of ITER-FEAT divertor cooling system has been developed for the analyses of thermal-hydraulic accidents as specified in the Accident Analysis Specifications (AAS-3) for the ITER-FEAT Generic Site Safety Report (GSSR). The model is based on data from the Safety Analysis Data List (SADL-3). The report presents the results of DV ex-vessel LOCA with plasma shutdown from MELCOR calculations. The intention is to verify previous analyses with ATHENA and INTRA to update parts of GSSR documenting the analysis of representative accident sequences for ITER
Availability note (English)
Available from INIS in electronic formFiles
33055848.pdf
Files
(1.1 MB)
Name | Size | Download all |
---|---|---|
md5:71658c31dffb9ef76665da2479f39604
|
1.1 MB | Preview Download |
Additional details
Publishing Information
- ISBN
- 91-7010-357-7
- Imprint Pagination
- 47 p.
- Report number
- STUDSVIK-ES--02-36
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 33055848
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Quality check status
- Yes
- Descriptors DEI
- DIVERTORS; ITER TOKAMAK; LOSS OF COOLANT; M CODES; REACTOR COOLING SYSTEMS; REACTOR SAFETY;
- Descriptors DEC
- ACCIDENTS; CLOSED PLASMA DEVICES; COMPUTER CODES; COOLING SYSTEMS; ENERGY SYSTEMS; REACTOR ACCIDENTS; REACTOR COMPONENTS; SAFETY; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS;
Optional Information
- Contract/Grant/Project number
- Project EFDA/01-599
- Notes
- 8 ref, 13 figs, 5 tabs