Published February 2014 | Version v1
Journal article

Optimum patient orientation for pelvic and hip radiography: A randomised trial

  • 1. Directorate of Radiology, Warrington and Halton Hospitals NHS Foundation Trust, Lovely Lane, Warrington WA5 1QG (United Kingdom)
  • 2. Royal Salford Hospitals NHS Foundation Trust, Salford (United Kingdom)
  • 3. Integrated Radiological Services Ltd, Liverpool (United Kingdom)
  • 4. Directorate of Radiography, University of Salford, Manchester (United Kingdom)

Description

Purpose: To investigate the effect of patient orientation on the radiation dose and image quality (IQ) for digital (DR) and computed radiography (CR) examinations of the pelvis. Methods: A randomised study was conducted using DR and CR X-ray equipment. The standard patient orientation of head towards (HT) the two outer Automatic Exposure Device (AED) chambers was compared with a group of patients with their head away (HA) from the two outer AED chambers. Collection of mAs, source-to-skin distance and kVp data facilitated the calculation of entrance surface dose (ESD) and effective dose (ED) which were compared between groups. Each image was graded independently by three observers. IQ data were analysed for inter-observer variability and statistical differences. Results: For DR pelvis examinations switching orientation (HT to HA) reduced the mean ESD and ED by 31% (P < 0.001), respectively. For CR examinations the dose reduction was greater between the two orientations (38%; P = 0.009). Examinations of the hips allowed dose reductions of around 50% when switching between orientations. For DR examinations minor reductions in IQ were seen and favoured the HT orientation (P = 0.03). For CR examinations there were no statistical differences in IQ between orientations. Conclusion: Switching patient orientation relative to the AED chambers can help optimise radiation dose. In order to facilitate this chamber position should be clearly marked on all equipment and patient orientation should be a consideration when tailoring individual examinations. For DR minor changes in IQ are a consequence of changing orientation and should be factored into the decision making

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radi.2013.09.002

Additional details

Identifiers

DOI
10.1016/j.radi.2013.09.002;
PII
S1078-8174(13)00094-1;

Publishing Information

Journal Title
Radiography (London 1995)
Journal Volume
20
Journal Issue
1
Journal Page Range
p. 22-32
ISSN
1078-8174

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45082001
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; IMAGES; OPTIMIZATION; ORIENTATION; PATIENTS; PELVIS; RADIATION DOSES; X-RAY EQUIPMENT
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DOSES; EQUIPMENT; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.