Published March 1983 | Version v1
Report

Ultrasoft X-ray diagnostics of REBEX plasma

  • 1. Ceskoslovenska Akademie Ved, Prague. Ustav Fyziky Plazmatu

Description

A combined detector of ultrasoft and hard X rays was developed for the diagnostics of REB-heated plasma in the REBEX machine. The detector consists of two separate arms. In the hard-X-ray arm a scintillation detector consisting of an aluminium-covered plastic scintillator and a photomultiplier is used. The aluminium protecting foil also serves as the photocathode of a photoemission detector in the soft-X-ray arm. To enhance the detector sensitivity, the emitted photoelectrons are first accelerated and then detected by another scintillator-photomultiplier system. Two identical detectors are necessary for measurements of electron temperature using the absorber method. Electron temperatures as low as 2o to 50 eV were determined using very thin absorber foils. Time variations of plasma temperature after beam injection and during magnetoacoustic oscillations of the hot plasma column were studied. (J.U.)

Additional details

Publishing Information

Imprint Title
12th Czechoslovak seminar on plasma physics and technology
Imprint Pagination
271 p.
Journal Page Range
p. 119-122.
Report number
IPPCZ--249

Conference

Title
12. Czechoslovak seminar on plasma physics and technology.
Dates
21-25 Mar 1983.
Place
Liblice (Czechoslovakia).