Prostatic artery embolization: radiation exposure to patients and staff
- 1. Nuclear Energy Department, Federal University of Pernambuco, Recife, PE (Brazil)
- 2. Interventional Radiology Department, Hospital da Restauração, Recife, PE (Brazil)
- 3. Urology Department, Hospital Getúlio Vargas, Recife, PE (Brazil)
- 4. Interventional Radiology Department, HC-FMUSP, Ribeirão Preto, SP (Brazil)
Description
The aim of this study was to evaluate the radiation doses to patients and staff received from the first cases of prostatic artery embolization (PAE) conducted in a public hospital in Recife, Brazil. Five PAE procedures for 5 men diagnosed with benign prostatic hyperplasia were investigated. In order to characterize patient exposure, dosimetric quantities, such as the air kerma-area product (P KA), the cumulative air kerma at the interventional reference point (Ka,r), the number of images, etc, were registered. To evaluate the possibility for deterministic effects, the peak skin dose (PSD) was measured using radiochromic films. For evaluation of personal dose equivalent and effective dose to the medical staff, thermoluminescent dosemeters (TLD-100) were used. The effective dose was estimated using the double dosimetry alghoritm of von Boetticher. The results showed that the mean patient's PSD per procedure was 2674.2 mGy. With regard to the medical staff, the mean, minimum and maximum effective doses estimated per procedure were: 18 μSv, 12 μSv and 21 μSv respectively. High personal equivalent doses were found for the feet, hands and lens of the eye, due to the use of multiple left anterior oblique projections and the improper use of the suspended lead screen and the lead curtain during procedures. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0952-4746/36/2/246Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Radiological Protection
- Journal Volume
- 36
- Journal Issue
- 2
- Journal Page Range
- p. 246-254
- ISSN
- 0952-4746
- CODEN
- JRPREA
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47102802
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ARTERIES; BRAZIL; CURTAINS; DOSE EQUIVALENTS; FEET; HANDS; HOSPITALS; KERMA; PATIENTS; RADIATION DOSES; SKIN; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY; VASCULAR DISEASES
- Descriptors DEC
- ARMS; BLOOD VESSELS; BODY; BUILDINGS; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DEVELOPING COUNTRIES; DISEASES; DOSEMETERS; DOSES; DOSIMETRY; LATIN AMERICA; LEGS; LIMBS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; ORGANS; SOUTH AMERICA