Published 2008 | Version v1
Miscellaneous Open

IMRT plan validation

Creators

  • 1. Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

Description

The lecture encompassed the following topics: Utility of radiographic and radiochromic film dosimetry; Diode and chamber arrays; 3D gel dosimetry; 4D dosimetry; Experimental design for dosimetry; In vivo measurements. and Portal dosimetry. In conclusion, the following pitfalls, potential errors and possible actions are pointed to: (i) Lacking algorithm in the TPS for tongue-and-groove effect. Action: Design and verify a new plan in which the tongue-and-groove effect plays a minor role. Discuss the issue with the TPS manufacturer. (ii) Systematic deviations between TPS calculations and ionisation chamber measurements at the isocentre for plans with many small segments due to uncertainties in the output factor calculation. Action: Rescale the number of MUs. Discuss the issue with the TPS manufacturer. (iii) Large regions with gamma values larger than one during repeated film measurements, while ionisation chamber measurements are correct. Action: Check if the film batch is not expired and if so repeat the measurement with a new batch. (iv) Missing significant errors, e.g., resulting from MLC displacements, due to the limited resolution of the measuring device. Action: Move the device in different directions and repeat the measurement. (v) Missing errors at other parts of the PTV or in OARs by performing only one ionisation chamber measurement or an independent MU calculation at a point. Action: Perform also measurements in a plane for representative clinical cases. (vi) Wrong parameter in the TPS for the definition of leaf position. Action: Understand and verify the definition of leaf position in your TPS. (P.A.)

Availability note (English)

Available from INIS in electronic form; Also available from the training course proceedings on CD-ROM: Dr. Josef Novotny, Na Homolce Hospital, Prague, Czech Republic, e-mail: Josef.Novotny@homolka.cz

Files

40003885.pdf

Files (1.6 MB)

Name Size Download all
md5:2454972fe8c8da14f7a25468de9f2fca
1.6 MB Preview Download

Additional details

Additional titles

Augmented title (English)
[Intensity-modulated radiation therapy]

Publishing Information

Publisher
Czech Association of Medical Physicists
Imprint Place
Prague (Czech Republic)
Imprint Pagination
23 p.
Report number
INIS-CZ--0060

Conference

Title
training course on clinical dosimetry and quality assurance for advanced radiation therapy techniques
Acronym
AAPM ISEP
Dates
16-20 Jun 2008
Place
Prague (Czech Republic)

INIS

Country of Publication
Czech Republic
Country of Input or Organization
Czech Republic
INIS RN
40003885
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DOSE-RESPONSE RELATIONSHIPS; DOSIMETRY; MONTE CARLO METHOD; PLANNING; QUALITY ASSURANCE; RADIATION DOSES; RECOMMENDATIONS
Descriptors DEC
CALCULATION METHODS; DOSES

Optional Information

Notes
PDF file for Adobe Acrobat obtained by transformation from a PowerPoint presentation consisting of 45 slides, delivered at the training course which was organized within the American Association of Physics in Medicine (AAPM) International Scientific Exchange Program (ISEP)