IMRT plan validation
Creators
- 1. Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)
Description
The lecture encompassed the following topics: Utility of radiographic and radiochromic film dosimetry; Diode and chamber arrays; 3D gel dosimetry; 4D dosimetry; Experimental design for dosimetry; In vivo measurements. and Portal dosimetry. In conclusion, the following pitfalls, potential errors and possible actions are pointed to: (i) Lacking algorithm in the TPS for tongue-and-groove effect. Action: Design and verify a new plan in which the tongue-and-groove effect plays a minor role. Discuss the issue with the TPS manufacturer. (ii) Systematic deviations between TPS calculations and ionisation chamber measurements at the isocentre for plans with many small segments due to uncertainties in the output factor calculation. Action: Rescale the number of MUs. Discuss the issue with the TPS manufacturer. (iii) Large regions with gamma values larger than one during repeated film measurements, while ionisation chamber measurements are correct. Action: Check if the film batch is not expired and if so repeat the measurement with a new batch. (iv) Missing significant errors, e.g., resulting from MLC displacements, due to the limited resolution of the measuring device. Action: Move the device in different directions and repeat the measurement. (v) Missing errors at other parts of the PTV or in OARs by performing only one ionisation chamber measurement or an independent MU calculation at a point. Action: Perform also measurements in a plane for representative clinical cases. (vi) Wrong parameter in the TPS for the definition of leaf position. Action: Understand and verify the definition of leaf position in your TPS. (P.A.)
Availability note (English)
Available from INIS in electronic form; Also available from the training course proceedings on CD-ROM: Dr. Josef Novotny, Na Homolce Hospital, Prague, Czech Republic, e-mail: Josef.Novotny@homolka.czFiles
40003885.pdf
Files
(1.6 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:2454972fe8c8da14f7a25468de9f2fca
|
1.6 MB | Preview Download |
Additional details
Additional titles
- Augmented title (English)
- [Intensity-modulated radiation therapy]
Publishing Information
- Publisher
- Czech Association of Medical Physicists
- Imprint Place
- Prague (Czech Republic)
- Imprint Pagination
- 23 p.
- Report number
- INIS-CZ--0060
Conference
- Title
- training course on clinical dosimetry and quality assurance for advanced radiation therapy techniques
- Acronym
- AAPM ISEP
- Dates
- 16-20 Jun 2008
- Place
- Prague (Czech Republic)
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 40003885
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSE-RESPONSE RELATIONSHIPS; DOSIMETRY; MONTE CARLO METHOD; PLANNING; QUALITY ASSURANCE; RADIATION DOSES; RECOMMENDATIONS
- Descriptors DEC
- CALCULATION METHODS; DOSES
Optional Information
- Notes
- PDF file for Adobe Acrobat obtained by transformation from a PowerPoint presentation consisting of 45 slides, delivered at the training course which was organized within the American Association of Physics in Medicine (AAPM) International Scientific Exchange Program (ISEP)