Published 1989
| Version v1
Book
Dual color radiometer imagery and test results
Creators
- 1. Magnavox Electro-Optical Systems, Mahwah, NJ (United States)
- 2. U.S. Army Combat Systems Test Activity, Aberdeen Proving Ground, MD (United States)
- 3. Center for Night Vision and Electro-Optics, Fort Belvoir, VA (United States)
Description
This paper presents a review of the technical characteristics of the Dual Color Radiometer and recent data and test results. The Dual Color Radiometer is a state-of-the-art device that provides simultaneous pixel to pixel registered thermal imagery in both the 3 to 5 and 8 to 12 micron regions. The device is unique in terms of its spatial and temperature resolution of less than 0.10 degrees C temperature and 0.10 milliradian spatial resolution. In addition, the device is tailored for use by the Automatic Target Recognizer (ATR) community
Additional details
Publishing Information
- Publisher
- SPIE Society of Photo-Optical Instrumentation Engineers.
- Imprint Place
- Bellingham, WA (United States)
- ISBN
- 0-8194-0145-5
- Imprint Title
- Optical radiation measurements. 2
- Imprint Pagination
- 282 p.
- Journal Page Range
- p. 39-63.
Conference
- Title
- Society of Photo-Optical Instrumentation Engineers conference.
- Dates
- 28-30 Mar 1989.
- Place
- Orlando, FL (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 23049572
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AUTOMATION; CALIBRATION; COLOR; DESIGN; IMAGES; OPTICAL SYSTEMS; PERFORMANCE TESTING; RADIOMETERS; REMOTE SENSING; TARGETS
- Descriptors DEC
- MEASURING INSTRUMENTS; OPTICAL PROPERTIES; ORGANOLEPTIC PROPERTIES; PHYSICAL PROPERTIES; RADIATION DETECTORS; TESTING
Optional Information
- Secondary number(s)
- CONF-890358--.