System Design Strategies of Post-Accident Monitoring System for a PGSFR in Korea
Creators
- Jang, Gwi-sook1
- Jeong, Kwang-il1
- Keum, Jong-yong1
- Seong, Seung-hwan2
- Commissariat a l'energie atomique et aux energies alternatives - CEA (France)
- Aix-Marseille Universite, Jardin du Pharo, 58 bd Charles Livon, 13284 Marseille Cedex 07 (France)
- Studie Centrum voor Kernenergie/Centre d'etude de l'energie nucleaire - SCK.CEN, Boeretang 200, 2400, Mol (Belgium)
- IEEE Nuclear and Plasma Sciences Society - NPSS, New York (United States)
- 1. Research Reactor Design and Engineering Division, Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)
- 2. SFR System Design Division, Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)
Description
Monitoring systems of a PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) in Korea provide alarms, integrity information in the reactor building, sodium-water reaction information in the steam generator, fuel failure information, and supporting information for maintenance and inspection. In particular, a Post-Accident Monitoring System (PAMS) provides primary information for operators to assess the plant conditions and perform their role in bringing the plant to a safe condition during an accident. Some PAM variables can be allocated as more two types. It is important for system designers to confirm the suitability of the selection of PAM variables. In addition, the PAMS is a position 4 display against common cause failures of safety I and C systems. The position 4 display should be independent and diverse from the safety I and C systems. The diversity of safety I and C equipment has led to an increase in the design and verification and validation cost. Thus, this paper proposes the system design strategies on the PAMS design problems of the PGSFR in KOREA. The results will be input into a conceptual system design for the PAMS of the PGSFR in KOREA. (authors)
Files
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- ANIMMA--2013-1270
Conference
- Title
- 3. international conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications
- Acronym
- ANIMMA 2013
- Dates
- 23-27 Jun 2013
- Place
- Marseille (France)
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 46071598
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCIDENTS; DESIGN; FAILURES; INFORMATION; INSPECTION; MAINTENANCE; MOLTEN METAL-WATER REACTIONS; MONITORING; REPUBLIC OF KOREA; SAFETY; SODIUM COOLED REACTORS; STEAM GENERATORS; VERIFICATION
- Descriptors DEC
- ASIA; BOILERS; DEVELOPING COUNTRIES; LIQUID METAL COOLED REACTORS; REACTORS; VAPOR GENERATORS
Optional Information
- Notes
- 3 Refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/