Separate effects testing and analyses to investigate liner tearing of the 1:6-scale reinforced concrete containment building
Creators
- 1. Sandia National Labs., Albuquerque, NM (United States)
Description
The overpressurization of a 1:6-scale reinforced concrete containment building demonstrated that liner tearing is a plausible failure mode in such structures under severe accident conditions. A combined experimental and analytical program was developed to determine the important parameters which affect liner tearing and to develop reasonably simple analytical methods for predicting when tearing will occur. Three sets of test specimens were designed to allow individual control over and investigation of the mechanisms believed to be important in causing failure of the liner plate. The series of tests investigated the effect on liner tearing produced by the anchorage system, the loading conditions, and the transition in thickness from the liner to the insert plate. Before testing, the specimens were analyzed using two- and three-dimensional finite element models. Based on the analysis, the failure mode and corresponding load conditions were predicted for each specimen. Test data and post-test examination of test specimens show mixed agreement with the analytical predictions with regard to failure mode and specimen response for most tests. Many similarities were also observed between the response of the liner in the 1:6-scale reinforced concrete containment model and the response of the test specimens. This work illustrates the fact that the failure mechanism of a reinforced concrete containment building can be greatly influenced by details of liner and anchorage system design. Further, it significantly increases the understanding of containment building response under severe conditions
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as TI95014950; NTIS; GPO.Files
27005914.pdf
Files
(7.4 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:ad01104311f5d4532f774e014157516e
|
7.4 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 283 p.
- Report number
- NUREG/CR--6184
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27005914
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- CONTAINMENT BUILDINGS; CONTAINMENT SHELLS; EXPERIMENTAL DATA; FAILURES; FINITE ELEMENT METHOD; IMAGES; MECHANICAL PROPERTIES; MITIGATION; PWR TYPE REACTORS; REINFORCED CONCRETE; STRESS ANALYSIS; WASTE STORAGE
- Descriptors DEC
- BUILDING MATERIALS; BUILDINGS; CALCULATION METHODS; COMPOSITE MATERIALS; CONCRETES; CONTAINMENT; DATA; ENRICHED URANIUM REACTORS; INFORMATION; MANAGEMENT; MATERIALS; NUMERICAL DATA; NUMERICAL SOLUTION; POWER REACTORS; REACTORS; REINFORCED MATERIALS; STORAGE; THERMAL REACTORS; WASTE MANAGEMENT; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Contract/Grant/Project number
- Contract AC04-94AL85000
- Funding organization
- Nuclear Regulatory Commission, Washington, DC (United States).
- Secondary number(s)
- SAND--92-1720.